AWG Basics
AWG is the North‑American wire‑gauge standard. Smaller numbers represent thicker wires. Every 6‑gauge decrease doubles the wire diameter; every 3‑gauge decrease doubles the cross‑sectional area and halves the resistance.

Common‑Use Wire‑Gauge Reference Table
AWG | Cross‑sectional Area (mm²) | Safe Current (A) | Typical Application
----|----------------------------|------------------|--------------------
24 | 0.20 | 2‑3 | Signal wires, sensors
22 | 0.33 | 3‑5 | Control wires, switches
20 | 0.52 | 5‑7 | Low‑power circuits
18 | 0.82 | 7‑10 | General automotive wiring
16 | 1.31 | 10‑13 | Relays, fans
14 | 2.08 | 15‑20 | Main power supply
12 | 3.31 | 20‑30 | High‑current applications

Two Key Derating Rules
Harness Derating: Bundled wires have poorer heat dissipation. Apply an 80 % derating factor for 4‑6 bundled wires; apply a 50 % derating factor for 10‑20 bundled wires.
Temperature Derating: Extra derating is required when ambient temperature exceeds 30 °C. Apply a 70 % derating factor at 60 °C ambient temperature.

Voltage‑Drop Calculation
For low‑voltage DC systems (12 V / 24 V), voltage‑drop constraints usually dominate wire‑gauge selection before current‑carrying capacity. Formula: V = 2 × Length(m) × Current(A) × Resistance(Ω/m). Target voltage drop ≤ 3 %.

Example: 12 V circuit with 10 A current and 15‑meter wiring. 16 AWG yields a 10 % voltage drop (unacceptable); upgrading to 12 AWG gives a 4 % voltage drop (marginally acceptable).

Three‑Step Selection Workflow
Check operating current → Select AWG rating
Calculate wiring distance → Verify voltage drop
Count bundled‑wire quantity → Apply derating factors

Send Inquiry